REFLUX DIVIDER

REFLUX DIVIDER - Manually Operated

Reflux divider are used to take off the distillate from the column. Usually a valve is to be fitted on distillate outlet which controls the reflux coarsely.
 

Cat. Ref.
DN
DN1
DN2
L
L1
Free Cross Section Cm2
Max. Product L/hr
 RDA3*
80
25
25
200
100
20
300
 RDA4*
100
25
25
250
150
50
500
 RDA6*
150
25
25
250
150
100
700
 RDA9*
225
25
25
375
150
150
900
 RDA12*
300
25
25
375
150
250
1100
 RDA16
400
40
40
500
200
350
1300
 RDA18
450
40
40
600
275
500
1500

DN2 is used for insertion of a thermometer pocket. A bellow is recommended on the distillate outlet DN1.

 
REFLUX DIVIDER -Magnetically Operated

These reflux divider are to be used with a electro-magnet and a timer. These have a swinging funnel mechanism which is operated magnetically from outside to remove the condensate or to return the reflux. Through this, correct control of reflux-ratio is possible. Funnel remains at 100% reflux position when magnet is inactive.
 

Cat. Ref.
DN
DN1
DN2
L
L1
Free Cross Section Cm2
Max. Product L/hr
 RHM3
80
25
25
375
75
20
90
 RHM4
100
25
25
400
75
50
180
 RHM6
150
25
25
450
100
100
300
 RHM9
225
25
25
550
100
150
500
 RHM12
300
25
25
700
100
250
650
 RHM16
400
40
40
800
150
350
1000
 RHM18
450
40
40
900
150
500
1300
 
THERMOMETER POCKETS FOR REFLUX DIVIDER

These thermometer pockets are to be used with reflux dividers or column sections. DN refers to the nominal diameter of the Reflux divider or Column.
 

Cat. Ref.
DN
DN1
d
L
 TP3*
80
25
12
75
 TP4*
100
25
12
100
 TP6*
150
25
12
125
 TP9*
225
25
12
175
 TP12*
300
25
12
225
 TP16
400
40
19
325
 TP18
450
40
19
375

* marked items are available fast.

 
LIQUID SEALS

Liquid seals are to be fitted on the distillate outlet of magnetically operated reflux divider. This prevent the passing of vapour passing directly to the receiver.
 

Cat. Ref.
DN
DN1
L
Type
 LS1*
25
25
200
A
 LS1.5
40
25
300
A
 LSV1
25
-
200
B

* marked items are available fast.